BIGEAGLE.SYS // AVL-21-01
LAT 41.3163 ° N / LON 72.9223 ° W
September 11 2001 · 1,445 REC
USPS_005
Document
STATE_005
Speech / Address
NATO_011
Document
STATE_004
Speech / Address
USPS_007
Document
DOD_BRIEF48
Speech / Address
APEC_001
Speech / Address
EU_021
Declaration
DOD_BRIEF47
Speech / Address
PRESIDENT_067
Speech / Address
USDA_001
Document
STATE_003
Speech / Address
DOD_BRIEF44
Speech / Address
BUTTERFIELD_001
Speech / Address
USPS_001
Message
GARVEY_002
Speech / Address
STATE_002
Speech / Address
DOD_BRIEF37
Speech / Address
STATE_DEPT_BRIEF028
Speech / Address
DOD_BRIEF39
Speech / Address
DOD_BRIEF38
Document
STATE_DEPT_BRIEF027
Speech / Address
DOD_BRIEF35
Speech / Address
DOD_BRIEF31
Document
STATE_DEPT_BRIEF016
Speech / Address
DOJ_BRIEF017
Speech / Address
USPS_003
Document
RATE
Document Type
Document
Date
2001
Period
21st Century
Status ARCHIVED
P
Y
TRANSCRIPT // ENG · be:avalon/sept11/cdc_009

CDC - To Update Public and Private Labs and Others on Rapid Anthrax Test 9:30 PM EDT

United States · 2001
Collection Status
ARCHIVED

AUTHOR — United States

September 11, 2001 : Attack on America

CDC - To Update Public and Private Labs and Others on Rapid Anthrax Test 9:30 PM EDT; October 18, 2001

October 18, 2001, 21:30 EDT (9:30 PM EDT)

Priority: Medium

Purpose: to update public and private labs and others on rapid anthrax test.

HAND-HELD IMMUNOASSAYS FOR DETECTION OF Bacillus anthracis SPORES

Hand-held assays (sometimes referred to as “Smart Tickets”) are sold commercially for the rapid detection of Bacillus anthracis. These assays are intended only for the screening of environmental samples. First responder and law enforcement communities are using these as instant screening devices and should forward any positive samples to authorities for more sensitive and specialized confirmatory testing. The results of these assays should not be used to make decisions about patient management or prophylaxis. The utility and validity of these assays are unknown.

At this time, CDC does not have enough scientific data to recommend the use of these assays. The analytical sensitivity of these assays is limited by the technology, and data provided by manufacturers indicate that a minimum of 10,000 spores is required to generate a positive signal. This number of spores would suggest a heavy contamination of the area (sample). Therefore a negative result does not rule out a lower level of contamination. Data collected from field use also indicate specificity problems with some of these assays. Some positive results have been obtained with spores of the non-anthrax Bacillus bacteria that may be found in the environment.

For these reasons, CDC has been asked to evaluate the sensitivity and specificity of the commercially available rapid, hand-held assays for B. anthracis. When this study is completed, results will be made available. Conclusions from this study are not expected in the near future.